Current position:Home - Vision Applied AOI - Variable Information Label Inspector
Product Name:Variable information Code Inspect System
Code 150 printing variable information code detection system for a variety of print variable information code as one dimensional bar codes and other electronic monitoring code quality testing, the main test variable message encoded in the marking process, the possible emergence repetition, loss, model error, reading disorders and other problems. The detection system finds and gives an alarm signal or rejecting, weed out the unqualified products.
- Descr
- Para
- Down
- Instruc li>
Code 150 printing variable information code detection system for a variety of print variable information code as one dimensional bar codes and other electronic monitoring code quality testing, the main test variable message encoded in the marking process, the possible emergence repetition, loss, model error, reading disorders and other problems. The detection system finds and gives an alarm signal or rejecting, weed out the unqualified products.
Code 150 printing variable information code detection system is easy to use and maintain, the software is intuitive and fast. Codes for the major printing variable information provides a reliable mass production shipments of quality assurance, thus reducing complaints to win long-term customer trust.
2 System Configuration
Hardware unit
Hardware components
1
Imaging unit
A high-speed line scan camera, a station supporting fixed focus lens, a set of linear sweep high brightness LED light source and power supply controller
2
Computing unit
Optional, configurable by the user. Includes: 1 industrial computer, a monitor and a keyboard and mouse, etc.
3
IO Interface Unit
Including encoders, IO controllers
4
Alarm unit
Optional configurations include sound and light alarm, etc.
5
Software Unit
Including high speed image acquisition and control, variable information is read, the variable information database comparison, database maintenance, image data storage, IO control and alarm output
6
Mechanical Structure unit
Contain fixed industrial machines, monitors, cameras, lenses, lighting, encoders and controllers of the mechanical structure
No
Project Index |
Technical Parameters
|
Maximum test speed |
150 m / min |
Material Type |
Various non-transparent printed labels and other printed packaging materials |
Variable message detections |
Number of repetition, loss, model error, reading disorders. |
Computing unit minimum configuration standards and requirements |
1) IPC CPU clock frequency: 2GHz or more; 2) Memory: Minimum 2 GB; 3) Hard Disk: minimum 160GB; 4) Display:> = 17-inch LCD display;
|
1。 System Installation:
For online installation, our engineers on-site surveying, installation and commissioning. If the machine is provided, does not require any installation.
2.Operating environment requirements:
(1) Power supply voltage: AC 220V;
(2) Power Consumption: <150W;
(3) Operating temperature range: -10 ~ 40 ℃;
(4) Operating relative humidity range: 40% to 75%;