中文版 English Favorites

Vision Applied AOI

Welcome, friends from Shenzhen City

Search

Current position:Home - Vision Applied AOI - Variable Information Label Inspector

Product Name:Variable information Code Inspect System


    Code 150 printing variable information code detection system for a variety of print variable information code as one dimensional bar codes and other electronic monitoring code quality testing, the main test variable message encoded in the marking process, the possible emergence repetition, loss, model error, reading disorders and other problems. The detection system finds and gives an alarm signal or rejecting, weed out the unqualified products.


  • Descr
  • Para
  • Down
  • Instruc
1 Introduction
Code 150 printing variable information code detection system for a variety of print variable information code as one dimensional bar codes and other electronic monitoring code quality testing, the main test variable message encoded in the marking process, the possible emergence repetition, loss, model error, reading disorders and other problems. The detection system finds and gives an alarm signal or rejecting, weed out the unqualified products.
Code 150 printing variable information code detection system is easy to use and maintain, the software is intuitive and fast. Codes for the major printing variable information provides a reliable mass production shipments of quality assurance, thus reducing complaints to win long-term customer trust.

2 System Configuration

No

Hardware unit

Hardware components

1

Imaging unit

A high-speed line scan camera, a station supporting fixed focus lens, a set of linear sweep high brightness LED light source and power supply controller

2

Computing unit

Optional, configurable by the user. Includes: 1 industrial computer, a monitor and a keyboard and mouse, etc.

3

IO Interface Unit

Including encoders, IO controllers

4

Alarm unit

Optional configurations include sound and light alarm, etc.

5

Software Unit

Including high speed image acquisition and control, variable information is read, the variable information database comparison, database maintenance, image data storage, IO control and alarm output

6

Mechanical Structure unit

Contain fixed industrial machines, monitors, cameras, lenses, lighting, encoders and controllers of the mechanical structure



Project Index


Technical Parameters


Maximum test speed

150 m / min

Material Type

Various non-transparent printed labels and other printed packaging materials

Variable message detections

Number of repetition, loss, model error, reading disorders.

Computing unit minimum configuration

standards and requirements

1) IPC CPU clock frequency: 2GHz or more;

2) Memory: Minimum 2 GB;

3) Hard Disk: minimum 160GB;

4) Display:> = 17-inch LCD display;


1。 System Installation:

For online installation, our engineers on-site surveying, installation and commissioning. If the machine is provided, does not require any installation.

2.Operating environment requirements:

(1) Power supply voltage: AC 220V;

(2) Power Consumption: <150W;

(3) Operating temperature range: -10 ~ 40 ℃;

(4) Operating relative humidity range: 40% to 75%;